杜远芳,赵天宇,平 华,李 杨.QuEChERS-超高效液相色谱-串联质谱法同时测定蔬菜废弃物中70种农药残留[J].食品安全质量检测学报,2025,16(3):154-161 |
QuEChERS-超高效液相色谱-串联质谱法同时测定蔬菜废弃物中70种农药残留 |
Simultaneous determination of 70 kinds of pesticide residues in vegetable wastes by QuEChERS-ultra performance liquid chromatography-tandem mass spectrometry |
投稿时间:2024-10-11 修订日期:2025-01-20 |
DOI: |
中文关键词: 蔬菜废弃物 农药残留 QuEChERS 超高效液相色谱-串联质谱 |
英文关键词:vegetable wastes pesticide residues QuEChERS ultra performance liquid chromatography-tandem mass spectrometry |
基金项目:国家重点研发计划(2022YFD2002101),北京市农林科学院科技创新能力建设专项(KJCX20230217) |
|
|
摘要点击次数: 73 |
全文下载次数: 39 |
中文摘要: |
目的 建立一种基于QuEChERS (Quick Easy Cheap Effective Rugged and Safe)前处理技术和超高效液相色谱-串联质谱法(ultra performance liquid chromatography-tandem mass spectrometry, UPLC-MS/MS)同时测定蔬菜废弃物中70种农药残留的分析方法。方法 蔬菜废弃物样品采用QuChERS方法提取净化, UPLC-MS/MS测定, 采用电喷雾电离源扫描, 多反应监测模式检测, 基质匹配标准曲线, 外标法定量。结果 70种农药在2.0~200.0 μg/L质量浓度范围内线性关系良好, 相关系数均大于0.99; 3个添加水平(0.002、0.004和0.020 mg/kg)下的平均回收率为61.7%~109.9%, 相对标准偏差为0.4%~9.7%; 检出限为0.0001~0.0020 mg/kg, 定量限为0.0003~0.0060 mg/kg。结论 该方法简单、快速、准确、灵敏度高, 可用于大批蔬菜废弃物中农药残留快速检测。 |
英文摘要: |
Objective To establish a method for the simultaneous determination of 70 kinds of pesticide residues
in vegetable wastes by QuChERS (Quick Easy Cheap Effective Rugged and Safe) and ultra performance liquid
chromatography-tandem mass spectrometry (UPLC-MS/MS). Methods Vegetable wastes samples were extracted
第 3 期 杜远芳, 等: QuEChERS-超高效液相色谱-串联质谱法同时测定蔬菜废弃物中 70 种农药残留 155
and purified by QuChERS method, then the samples were detected by UPLC-MS/MS, and the electrospray ionization
source was used simultaneous scanning, detected under multiple reaction monitoring mode, matrix-matched
calibration curve, and quantified by external standard method. Results The 70 kinds of target pesticides
exhibited great linear relationships within the concentration range of 2.0–200.0 μg/L, with linear correlation
coefficients were all greater than 0.99. The average recoveries ranged from 61.7% to 109.9%, the relative standard
deviations were 0.4%–9.7%, with 3 addition levels at 0.002, 0.004 and 0.020 mg/kg. The limits of detection were
in the range of 0.0001 to 0.0020 mg/kg, and the limits of quantification were in the range of 0.0003–0.0060 mg/kg.
Conclusion This method is easy operation, fast, accurate, and good sensitivity, which is suitable for the
simultaneous detection of pesticide residues in a large number of vegetable wastes samples. |
查看全文 查看/发表评论 下载PDF阅读器 |
|
|
|