孔庆龙,荆 雯,杨云程,徐 怡,游 燕.硬糖类产品中桉叶素的含量测定[J].食品安全质量检测学报,2021,12(3):919-924
硬糖类产品中桉叶素的含量测定
Determination of the content of cineole in hard candy
投稿时间:2020-09-21  修订日期:2021-01-08
DOI:
中文关键词:  桉叶素  硬糖  检测方法
英文关键词:cineole  hard candy  detection method
基金项目:国家重点研发计划项目(2017YFC1702506)
作者单位
孔庆龙 云南省药物研究所;云南省中药和民族药新药创制企业重点实验室 
荆 雯 昆明理工大学财务处 
杨云程 暨南大学生命科学技术学院 
徐 怡 云南省药物研究所;云南省中药和民族药新药创制企业重点实验室 
游 燕 云南省药物研究所;云南省中药和民族药新药创制企业重点实验室 
AuthorInstitution
KONG Qing-Long Yunnan Institute of Materia Medica;Yunnan Province Company Key Laboratory for TCM and Ethnic Drug of New Drug Creation 
JING Wen Finance office, Kunming University of Science and Technology 
YANG Yun-Cheng College of Life Science and Technology, Jinan University 
XU Yi Yunnan Institute of Materia Medica;Yunnan Province Company Key Laboratory for TCM and Ethnic Drug of New Drug Creation 
YOU Yan Yunnan Institute of Materia Medica;Yunnan Province Company Key Laboratory for TCM and Ethnic Drug of New Drug Creation 
摘要点击次数: 614
全文下载次数: 373
中文摘要:
      目的 建立适用于硬糖类产品中桉叶素的检测方法。方法 采用气相色谱法测定硬糖中桉叶素的含量。采用Agilent HP-INNOWAX毛细管色谱柱(柱长为30 m, 内径为0.32 mm, 膜厚为0.25 μm), 采用顶空进样, 进样量为5 mL, 炉温为85 ℃, 平衡时间为30 min, 进样口温度为150℃, 柱温为程序升温: 初始温度70 ℃, 以5 ℃/min的升温速率升温至125 ℃, 保持2 min, 再以20 ℃/min的升温速率升温至200 ℃, 保留 5 min; 检测器温度为180 ℃, 载气流速为1.0 mL/min。结果 桉叶素回归方程Y=8622.2X-32.028, 相关系数r2为0.9998, 线性范围为0.00284~0.56720 mg/mL, 加样回收率为104.31%。结论 该法简便、准确、专属性强、重复性好, 经方法学验证, 本法可用于硬糖类产品中桉叶素的含量测定。
英文摘要:
      Objective To establish a method for the determination of cineole inhard candy. Methods The content of eucalyptus in hard candy was determined by gas chromatography. Agilent HP-INNOWAXCapillary chromatographic column (30 m×0.32 mm, 0.25 μm)was used. Headspace sample was used for injection, the amount of sample was 5 mL, the furnace temperature was 85 ℃, the equilibrium time was 30 min, and the inlet temperature was 150 ℃.The column temperature was programmed: the initial temperature was 70 ℃, and the temperature was increased to 125 ℃ at a rate of 5 ℃/min for 2 min. Then the temperature was increased to 200 ℃ at a rate of 20 ℃/min for 5 min. The detector temperature was 180 ℃, and the flow rate of carrier gas was 1.0 mL/min. Results The regression equation was Y=8622.2X?32.028, the correlation coefficient r2was 0.9998, the linear range were 0.00284?0.56720 mg/mL, and the recovery was 104.31%. Conclusion This method is simple, accurate, specific, and reproducible. It has been verified by methodology that this method can be used to determine the content of cineole in hard candy products.
查看全文  查看/发表评论  下载PDF阅读器