钟钰,林海丹,官咏仪,张美金,金梦,陈毓芳,宋阳.高效液相色谱法测定营养强化剂中氯化高铁血红素的含量[J].食品安全质量检测学报,2018,9(20):5428-5432
高效液相色谱法测定营养强化剂中氯化高铁血红素的含量
Determination of hemin in nutrient supplement by high performance liquid chromatography
投稿时间:2018-01-05  修订日期:2018-10-09
DOI:
中文关键词:  营养强化剂  氯化高铁血红素  高效液相色谱法
英文关键词:nutrient supplement, hemin, high performance chromatography
基金项目:
作者单位
钟钰 广东出入境检验检疫局技术中心 
林海丹 广东出入境检验检疫局技术中心 
官咏仪 广东出入境检验检疫局技术中心 
张美金 广东出入境检验检疫局技术中心 
金梦 广东出入境检验检疫局技术中心 
陈毓芳 广东出入境检验检疫局技术中心 
宋阳 广东出入境检验检疫局技术中心 
AuthorInstitution
ZHONG Yu Inspection and Quarantine Technology Center,Guangdong-Entry-Exit Inspection and Quarantine Bureau,GuangZhou,510623 
LIN Hai-Dan Inspection and Quarantine Technology Center,Guangdong-Entry-Exit Inspection and Quarantine Bureau,GuangZhou,510623 
GUAN Yong-Yi Inspection and Quarantine Technology Center,Guangdong-Entry-Exit Inspection and Quarantine Bureau,GuangZhou,510623 
ZHANG Mei-Jin Inspection and Quarantine Technology Center,Guangdong-Entry-Exit Inspection and Quarantine Bureau,GuangZhou,510623 
JIN Meng Inspection and Quarantine Technology Center,Guangdong-Entry-Exit Inspection and Quarantine Bureau,GuangZhou,510623 
Chen Yu-Fang Inspection and Quarantine Technology Center,Guangdong-Entry-Exit Inspection and Quarantine Bureau,GuangZhou,510623 
Song Yang Inspection and Quarantine Technology Center,Guangdong-Entry-Exit Inspection and Quarantine Bureau,GuangZhou,510623 
摘要点击次数: 669
全文下载次数: 444
中文摘要:
      目的 建立高效液相色谱法(high performance chromatography, HPLC)测定营养强化剂中氯化高铁血红素的含量。方法 采用0.1 mol/L氢氧化钠溶液提取样品, 以Agilent TC-C18为色谱分析柱, 流动相为0.6%乙酸:甲醇=30:70(V:V), 流速1.0 mL/min, 柱温35 ℃, 检测波长399 nm, 采用高效液相色谱-二极管阵列检测器进行检测, 以峰面积外标法定量。结果 该方法在40~140 mg/L范围内线性关系良好, 相关系数r为0.9993, 相对标准偏差(relative standard deviation, RSD)小于1.38%。结论 该方法操作简单、快速、准确、灵敏度高, 适合测定营养强化剂中氯化高铁血红素的含量。
英文摘要:
      Objective To establish a method for determination of hemin in nutrient supplement by high performance chromatography (HPLC). Method The sample was extracted with 0.1 mol/L sodium hydroxide solution, and was analyzed with Agilent TC-C18. The mobile phase was 0.6% acetic acid: methanol=30:70 (V:V), the flow rate was 1.0 mL/min, and the column temperature was 35 ℃. The detection wavelength was 399 nm, and the detection was performed by a high performance liquid chromatography-diode array detector. And the samples were quantified by peak area external standard method. Result The method had a good linear relationship in the range of 40-140 mg/L, the correlation coefficient r was 0.9993, and the relative standard deviations (RSDs) were less than 1.38%. Conclusion The method is simple, rapid, accurate and sensitive, which is suitable for the determination of hemin in nutrient supplement.