孟慧琴,徐 琴,宫 萍,郝鹏飞,徐 丽,吕 宁,翟丽娜.婴幼儿配方食品和乳粉中维生素C的测定[J].食品安全质量检测学报,2016,7(4):1448-1451
婴幼儿配方食品和乳粉中维生素C的测定
Determination of vitamin C in foods for infants and young children,
投稿时间:2016-02-02  修订日期:2016-03-29
DOI:
中文关键词:  维生素C  高效液相色谱法  婴幼儿食品
英文关键词:vitamin C  high performance liquid chromatography  foods for infants and young children
基金项目:
作者单位
孟慧琴 山东出入境检验检疫局食品农产品检测中心 
徐 琴 山东出入境检验检疫局食品农产品检测中心 
宫 萍 山东出入境检验检疫局食品农产品检测中心 
郝鹏飞 山东出入境检验检疫局食品农产品检测中心 
徐 丽 山东出入境检验检疫局食品农产品检测中心 
吕 宁 山东出入境检验检疫局食品农产品检测中心 
翟丽娜 山东出入境检验检疫局食品农产品检测中心 
AuthorInstitution
MENG Hui-Qin Food and Agricultural Products Testing Agency of Shandong Entry-Exit Inspection and Quarantine Bureau 
XU Qin Food and Agricultural Products Testing Agency of Shandong Entry-Exit Inspection and Quarantine Bureau 
GONG Ping Food and Agricultural Products Testing Agency of Shandong Entry-Exit Inspection and Quarantine Bureau 
HAO Peng-Fei Food and Agricultural Products Testing Agency of Shandong Entry-Exit Inspection and Quarantine Bureau 
XU Li Food and Agricultural Products Testing Agency of Shandong Entry-Exit Inspection and Quarantine Bureau 
LV Ning Food and Agricultural Products Testing Agency of Shandong Entry-Exit Inspection and Quarantine Bureau 
ZHAI Li-Na Food and Agricultural Products Testing Agency of Shandong Entry-Exit Inspection and Quarantine Bureau 
摘要点击次数: 1485
全文下载次数: 1146
中文摘要:
      目的 建立一种前处理简单、仪器条件稳定、准确高效的婴幼儿配方食品和乳粉中维生素C的检测方法。方法 用含有三(2-羧乙基)膦(TCEP)的三氯乙酸(TCA)对样品中的维生素C进行提取, C18柱色谱分离, 流动相为含TCEP与癸胺作为离子对试剂和pH 5.4的醋酸钠的混合水溶液, 然后在紫外检测器265 nm处进行检测。结果 本方法的相对标准偏差(n=6)在0.36%~3.2%之间, 平均回收率为 88.5%~97.9%, 线性相关系数r2大于0.9999。结论 本方法实验前处理简单, 干扰因素少; 仪器条件稳定, 灵敏度高, 重复性好; 适合婴幼儿配方食品和乳粉复杂基质样品的测定。
英文摘要:
      Objective An accurate and efficient method was developed in order to solve problems existed in the detection of vitamin C in milk powder and formula foods for infant and young children , which had simple pretreatment and stable instrument conditions. Methods Vitamin C was extracted from samples by trichloroacetic acid (TCA) with tris (2-carboxyethyl) phosphine (TCEP) as a reducing agent, and then determined by ultraviolet detector at 265 nm. Samples were separated by a C18 column with sodium acetate (pH=5.4) as the eluent, combined with TCEP and decylamine as an ion-pairing agent. Results The relative standard deviation (n=6) of this method was between 0.36%~3.2%, the average recovery was 88.5%~97.9%, and the linear correlation coefficient was greater than 0.9999. Conclusion The established method is simple with less interference factors, and instrument conditions are stable, sensitive with good repeatability, which is suitable for the detection of vitamin C in complex sample matrix such as infant formula milk powder.