于艳丽.高效液相色谱-二极管阵列检测器测定兽药、保健食品中茶碱、二羟丙茶碱和盐酸二氧丙嗪[J].食品安全质量检测学报,2021,12(7):2679-2685
高效液相色谱-二极管阵列检测器测定兽药、保健食品中茶碱、二羟丙茶碱和盐酸二氧丙嗪
Determination of theophylline, diprophylline and dioxopromethazine in veterinary drugs and health food by high performance liquid chromatography-photodiode array detector
投稿时间:2020-11-20  修订日期:2021-04-12
DOI:
中文关键词:  茶碱  二羟丙茶碱  盐酸二氧丙嗪  高效液相色谱法  二极管阵列检测器
英文关键词:theophylline  diprophylline  dioxopromethazine  high performance liquid chromatography  photodiode array detector
基金项目:上海杉达学院科研基金项目(2020YB17)
作者单位
于艳丽 上海杉达学院 
AuthorInstitution
YU Yan-Li Shanghai Sanda University 
摘要点击次数: 551
全文下载次数: 417
中文摘要:
      目的 建立高效液相色谱-二极管阵列检测器(high performance liquid chromatography- photodiode array detector, HPLC-PDA)检测茶碱、二羟丙茶碱和盐酸二氧丙嗪3种平喘类药物成分的检测方法。方法 以水-甲醇(70:30, V:V)为流动相, 流速为1.0 mL/min, 检测波长为272 nm同时测定茶碱和二羟丙茶碱; 以 0.025 mol/L磷酸溶液-乙腈(72:28, V:V)为流动相, 流速为1.0 mL/min, 检测波长264 nm测定盐酸二氧丙嗪。 结果 茶碱和二羟丙茶碱能得到良好分离, 在 1~50 μg/mL范围内线性关系良好, 相关系数大于0.9999, 在不同样品中的回收率分别为95.9%~105.9%、95.4%~104.2%。盐酸二氧丙嗪在1~50 μg/mL范围内线性关系良好, 相关系数大于0.9990, 在不同样品中的回收率在95.9%~104.8%之间。结论 本方法操作简单, 准确度高, 可对兽药、保健食品中非法添加的3种平喘类药物进行定性和定量检测。
英文摘要:
      Objective To establish a method for the determination of 3 kinds of antiasthmatic drug components (theophylline, diprophylline and dioxopromethazine) by high performance liquid chromatography-photodiode array detector (HPLC-PDA). Methods Theophylline and diprophylline were simultaneously determined on conditions as follows: water-methanol (70:30, V:V) was used as the mobile phase, the flow rate was 1.0 mL/min, and the detection wavelength was 272 nm. Dioxopromethazine was determined on conditions as follows: 0.025 mol/L phosphoric acid acetonitrile (72:28, V:V) was used as the mobile phase, the flow rate was 1.0 mL/min, and the detection wavelength was 264 nm. Results Theophylline and diprophylline could be separated well. The linear range was 1?50 μg/mL, and the correlation coefficient was more than 0.9999. The recoveries of theophylline and diprophylline in different samples were 99.25.9%-101.85.9% and 96.05.4%-103.64.2%, respectively. The linear range of promethazine hydrochloride was 1?50 μg/mL, and the correlation coefficient was more than 0.9990. The recoveries of dioxopromethazine in different samples ranged from 95.9% to 104.8%. Conclusion The method is simple and accurate, and can be used for qualitative and quantitative detection of 3 kinds of antiasthmatic drugs illegally added in veterinary drugs and heathy food.