陆雨顺,赵 洋,王泽帅,刘松鑫,李珊珊,孙印石.超高效液相色谱-串联四极杆-静电场轨道阱-线性离子阱质谱法测定中药中7种杂环胺类物质[J].食品安全质量检测学报,2021,12(4):1427-1434
超高效液相色谱-串联四极杆-静电场轨道阱-线性离子阱质谱法测定中药中7种杂环胺类物质
Determination of seven heterocyclic aromatic amines in Chinese medicine by ultra performance liquid chromatography-quadrupole-orbitrap- linear ion trap mass spectrometry
投稿时间:2020-09-13  修订日期:2021-01-14
DOI:
中文关键词:  山楂  麦芽  神曲  鸡内金  炮制品  杂环胺
英文关键词:Crataegi fructus  malt  Massa medicate  Galli gigerii edothelium corneum  processed products  heterocyclic aromatic amines
基金项目:中国农业科学院科技创新工程项目(CAAS-ASTIP-2016-ISAPS)
作者单位
陆雨顺 中国农业科学院特产研究所 
赵 洋 中国农业科学院特产研究所 
王泽帅 中国农业科学院特产研究所 
刘松鑫 中国农业科学院特产研究所 
李珊珊 中国农业科学院特产研究所 
孙印石 中国农业科学院特产研究所 
AuthorInstitution
LU Yu-Shun Institute of Special Animal and Plant Sciences, China Academy of Agricultural Sciences 
ZHAO Yang Institute of Special Animal and Plant Sciences, China Academy of Agricultural Sciences 
WANG Ze-Shuai Institute of Special Animal and Plant Sciences, China Academy of Agricultural Sciences 
LIU Song-Xin Institute of Special Animal and Plant Sciences, China Academy of Agricultural Sciences 
LI Shan-Shan Institute of Special Animal and Plant Sciences, China Academy of Agricultural Sciences 
SUN Yin-Shi Institute of Special Animal and Plant Sciences, China Academy of Agricultural Sciences 
摘要点击次数: 731
全文下载次数: 467
中文摘要:
      目的 建超高效液相色谱-串联四极杆-静电场轨道阱-线性离子阱质谱法检测中药中7种杂环胺类物质的分析方法。方法 以0.1%的甲酸水溶液和乙腈为流动相, 采用Waters Acquity UPLC BEH C18反相色谱柱(100 mm×2.1 mm, 1.7 μm)梯度洗脱, 流速为0.3 mL/min, 在正离子模式下扫描, 高分辨一级定量模式下测定。结果 7种杂环胺类物质线性关系良好, 相关系数大于0.957, 检出限为0.02 μg/L, 在3个加标水平下, 杂环胺类物质在焦山楂、焦麦芽、焦神曲和炒鸡内金4种中药中的平均回收率为72.1%~119.6%, 相对标准偏差为0.6%~16.4%。结论 该方法具有灵敏度高和准确性强等优点, 适用于中药中杂环胺的精确检测。
英文摘要:
      Objective To establish an analytical method for the simultaneous determination of seven heterocyclic aromatic amines in Chinese medicine by ultra-high performance liquid chromatography- quadrupole-electrostatic field track trap-linear ion trap mass spectrometry. Methods The separation was achieved by Waters Acquity UPLC BEH C18 column(100 mm×2.1 mm, 1.7 μm)and a gradient elution with the mobile phases of acetonitrile and 0.1% formic acid. The flow rate was set at 0.3 mL/min. The target compound was scanned in the positive ion mode and analyzed in high-resolution quantitative mode. Results The linear relationship of the seven heterocyclic amines was good, and the correlation coefficients of the seven heterocyclic aromatic amines were all above 0.957 and the limits of detection were 0.02 μg/L. The recoveries of the seven heterocyclic aromatic amines in all samples were 72.1%?119.6%, the relative standard deviations were 0.6%?16.4%. Conclusion This method has the advantages of high sensitivity and accuracy, and is suitable for the accurate detection of heterocyclic amines in traditional Chinese medicine.
查看全文  查看/发表评论  下载PDF阅读器