李跃红,徐孟怀,冉茂乾,赵 阳,焦彦朝.葡萄酒中苯甲酸的测定测量审核结果分析[J].食品安全质量检测学报,2021,12(3):1026-1031
葡萄酒中苯甲酸的测定测量审核结果分析
Analysis of measurement audit results for the determination of benzoic acid in wine
投稿时间:2020-08-14  修订日期:2020-11-10
DOI:
中文关键词:  葡萄酒  苯甲酸  测量审核  高效液相色谱法  综合评价—
英文关键词:wine  benzoic acid  measurement audit  high performance liquid chromatography  comprehensive evaluation
基金项目:海关总署科研计划项目(2018IK053)
作者单位
李跃红 六盘水市口岸服务中心;贵阳海关综合技术中心果蔬实验室 
徐孟怀 六盘水市口岸服务中心;贵阳海关综合技术中心果蔬实验室 
冉茂乾 六盘水市口岸服务中心;贵阳海关综合技术中心果蔬实验室 
赵 阳 六盘水市口岸服务中心;贵阳海关综合技术中心果蔬实验室 
焦彦朝 贵阳海关综合技术中心果蔬实验室 
AuthorInstitution
LI Yue-Hong Liupanshui Port Service Center;Laboratory of Fruit and Vegetable Products of Comprehensive Technical Center of Guiyang Customs 
XU Meng-Huai Liupanshui Port Service Center;Laboratory of Fruit and Vegetable Products of Comprehensive Technical Center of Guiyang Customs 
RAN Mao-Qian Liupanshui Port Service Center;Laboratory of Fruit and Vegetable Products of Comprehensive Technical Center of Guiyang Customs 
ZHAO Yang Liupanshui Port Service Center;Laboratory of Fruit and Vegetable Products of Comprehensive Technical Center of Guiyang Customs 
JIAO Yan-Chao Laboratory of Fruit and Vegetable Products of Comprehensive Technical Center of Guiyang Customs 
摘要点击次数: 556
全文下载次数: 368
中文摘要:
      目的 参加MA-GW-010项目“葡萄酒中苯甲酸的测定”测量审核, 提升实验室对食品中苯甲酸的检测能力和实验室综合检测水平。方法 以GB 5009.28—2016《食品安全国家标准 食品中苯甲酸、山梨酸和糖精钠的测定》第一法为依据, 采用高效液相色谱法二极管阵列检测器对样品进行检测, 并按照实验室多种内部质量控制方式对检测结果进行综合评价。结果 MA20-839样品中苯甲酸检测结果为59.4 mg/L, 样品Z值为-0.6, 检测结果满意。结论 本次测量审核样本检测结果与制样单位反馈结果一致, 本次测量审核不仅丰富了检测人员的检测经验, 同时也提高了实验室的检测水平。
英文摘要:
      Objective To improve the benzoic acid detection ability and laboratory comprehensive detection level in food by participating in the MA-GW-010 project Determination of benzoic acid in wine measurement audit. Methods Based on the first method of GB 5009.28—2016 National food safety standard-Determination of benzoic acid, sorbic acid and sacconin sodium in food, the samples were detected by high performance liquid chromatography (HPLC) with diode array detector, and the detection results were comprehensively evaluated according to various internal quality control methods in the laboratory. Results The content of benzoic acid in the MA20-839 was 59.4 mg/L, and the Z-score was -0.6, meaning that the detection results was regarded as satisfaction. Conclusion The results of this measurement audit sample are consistent with the feedback results of sample preparation units, which enriches the detection experience of the testing personnel and improves the detection level of the laboratory.
查看全文  查看/发表评论  下载PDF阅读器