中文关键词:  酸价  不确定度  冷溶剂指示剂滴定法  冷溶剂自动电位滴定法  热乙醇指示剂滴定法
英文关键词:acid value  uncertainty  cold solvent indicator titration  cold solvent automatic potentiometric titration  thermo ethanol indicatora titration
基金项目:广东省科技计划项目(2016A040403066)、广州市科技计划项目(201806010093)、广东省科学院项目(2016GDASPT-010)
作者单位
张晶 广东省生物工程研究所(广州甘蔗糖业研究所) 
钟宏星 广东省生物工程研究所(广州甘蔗糖业研究所) 
曾史俊 广东省生物工程研究所(广州甘蔗糖业研究所) 
钱晓静 广东省生物工程研究所(广州甘蔗糖业研究所) 
AuthorInstitution
ZHANG Jing Guangdong Provincial Bioencineering Institute(Guangzhou Sugarcane Industry Research Institute) 
ZHONG HONG XING Guangdong Provincial Bioencineering Institute(Guangzhou Sugarcane Industry Research Institute) 
ZENG Shi-Jun Guangdong Provincial Bioencineering Institute(Guangzhou Sugarcane Industry Research Institute) 
QIAN Xiao-Jing Guangdong Provincial Bioencineering Institute(Guangzhou Sugarcane Industry Research Institute) 
摘要点击次数: 1047
全文下载次数: 656
中文摘要:
      目的 通过GB/T 5009.229-2016《食品安全国家标准 食品中酸价的测定》中的3种测定酸价的方法中不确定度的评定结果, 为实际应用中选择合适的方法来对油脂的酸价进行测定方法提供参考。方法 通过对3种测定油脂酸价的方法进行不确定度来源分析, 建立数学模型方法, 进行不确定度评定, 计算出各种方法不同的来源对不确定度影响的大小。结果 冷溶剂自动电位滴定法的合成标准不确定度最小, 其次是热乙醇指示剂滴定法, 冷溶剂指示剂滴定法的不确定度最大。结论 冷溶剂自动电位滴定法所测量得到的结果最接近真实值, 更有使用价值。
英文摘要:
      Objective Through the evaluation results of uncertainty in three methods for determining acid valence in GB/T 5009.229-2016 National food safety standard-Determination of acid value, to provides a reference for selecting an appropriate method for the determination of acid price of oil in practical application. Methods By analyzing the sources of uncertainty of three methods for the determination of lipid acid value, a mathematical model method was established to evaluate the uncertainty, and the influence of different sources of various methods on the uncertainty was calculated. Results The synthetic standard uncertainty of the cold solvent automatic potentiometric titration was the smallest, followed by the thermo ethanol indicator titration, and the uncertainty of the cold solvent indicator titration was the largest. Conclusion The results obtained by the cold solvent automatic potentiometric titration method are the closest to the real value and more valuable.