吴春香,刘志楠,赵 源,宋晓东,喻东威,刘萍萍,王俊英,莎日娜,张利珍.酶联免疫吸附法快速检测婴儿配方奶粉中乳铁蛋白含量[J].食品安全质量检测学报,2018,9(4):803-807
酶联免疫吸附法快速检测婴儿配方奶粉中乳铁蛋白含量
Rapid detection of lactoferrin content in infant formula by enzyme-linked immunosorbent assay
投稿时间:2017-09-04  修订日期:2018-01-22
DOI:
中文关键词:  酶联免疫吸附法  乳铁蛋白  快速检测
英文关键词:enzyme-linked immunosorbent assay  lactoferrin  rapid detection
基金项目:国家重大科学仪器设备开发专项(2013YQ14037108)
作者单位
吴春香 内蒙古欧世蒙牛乳制品有限责任公司 
刘志楠 内蒙古欧世蒙牛乳制品有限责任公司 
赵 源 内蒙古欧世蒙牛乳制品有限责任公司 
宋晓东 内蒙古蒙牛乳业(集团)股份有限公司 
喻东威 内蒙古蒙牛乳业(集团)股份有限公司 
刘萍萍 内蒙古蒙牛乳业(集团)股份有限公司 
王俊英 内蒙古欧世蒙牛乳制品有限责任公司 
莎日娜 内蒙古欧世蒙牛乳制品有限责任公司 
张利珍 内蒙古欧世蒙牛乳制品有限责任公司 
AuthorInstitution
WU Chun-Xiang Inner Mongolia Mengniu Arla Dairy Products Co., Ltd. 
LIU Zhi-Nan Inner Mongolia Mengniu Arla Dairy Products Co., Ltd. 
ZHAO Yuan Inner Mongolia Mengniu Arla Dairy Products Co., Ltd. 
SONG Xiao-Dong Inner Mongolia Mengniu Dairy Industry (Group) Limited Company 
YU Dong-Wei Inner Mongolia Mengniu Dairy Industry (Group) Limited Company 
LIU Ping-Ping Inner Mongolia Mengniu Dairy Industry (Group) Limited Company 
WANG Jun-Ying Inner Mongolia Mengniu Arla Dairy Products Co., Ltd. 
SHA Ri-Na Inner Mongolia Mengniu Arla Dairy Products Co., Ltd. 
ZHANG Li-Zhen Inner Mongolia Mengniu Arla Dairy Products Co., Ltd. 
摘要点击次数: 1217
全文下载次数: 967
中文摘要:
      目的 采用乳铁蛋白快速检测试剂盒, 通过酶联免疫吸附法定量测定婴儿配方奶粉中的乳铁蛋白含量, 并验证该方法的准确性、稳定性和可靠性。方法 按照试剂盒操作说明制作标准曲线, 选取乳铁蛋白阴性样品进行添加回收实验, 验证方法的准确性; 选取一个乳铁蛋白阳性样品, 重复检测6次, 计算结果偏差, 验证方法的稳定性; 选取12个乳铁蛋白阳性样品, 分别采用试剂盒方法和高效液相色谱法进行检测, 对比2种方法的检测结果, 验证试剂盒方法的可靠性。结果 试剂盒检出限为2 mg/100 g; 试剂盒检测方法回收率在101.6%~109%; 相对标准偏差(relative standard deviation, RSD)为5.34%; 试剂盒方法检测结果与标签值的偏差为?6.90%~6.45%, 和高效液相色谱法检测结果的偏差为?6.45%~6.9%, 说明试剂盒方法具有很好的可靠性。 结论 乳铁蛋白试剂盒检测方法灵敏度高、操作简单, 能快速准确地测定婴儿配方奶粉中的乳铁蛋白含量。
英文摘要:
      Objective To detect the content of lactoferrin in infant formula by enzyme-linked immunosorbent assay with lactoferrin rapid detection kit, and verify the accuracy, stability and reliability of the method. Methods The standard curve was made according to the instruction of the kit. The lactoferrin negative sample was selected for the spiking recovery experiment to test the accuracy of the method. A lactoferrin positive sample was repeated 6 times to verify the stability of the method. Twelve lactoferrin positive samples were selected and tested by the kit and HPLC. The test results of the 2 methods were compared to verify the reliability of the kit method. Results The limit of detection of the kit was 2 mg/100 g. The recovery rate of the kit method was 101.6%~109%. The relative standard deviation was 5.34%. The deviation between the kit result and the label value was ?6.90%~6.45% and the deviation between the kit result and the HPLC result was ?6.45%~6.9%, which indicated that the kit method had good reliability. Conclusion Lactoferrin kit detection method has high sensitivity and simple operation, which can quickly and accurately determine the lactoferrin content in infant formula.
查看全文  查看/发表评论  下载PDF阅读器