龚琴,王芳斌,孙桂芳,蒋建,陈 理,肖敏,刘赛,陈雄.食用油过氧化值快速检测试剂盒的研制及其 性能评价[J].食品安全质量检测学报,2016,7(10):4145-4149
食用油过氧化值快速检测试剂盒的研制及其 性能评价
Research and performance evaluation of rapid detection kits for the determination of peroxide value in oils
投稿时间:2016-09-30  修订日期:2016-10-25
DOI:
中文关键词:  过氧化值  快速检测  试剂盒  食用油脂
英文关键词:peroxide value  rapid detection  kit  fat and oil
基金项目:
作者单位
龚琴 湖南省食品质量监督检验研究院 
王芳斌 湖南省食品质量监督检验研究院 
孙桂芳 湖南省食品质量监督检验研究院 
蒋建 湖南省食品质量监督检验研究院 
陈 理 湖南省食品质量监督检验研究院 
肖敏 湖南省食品质量监督检验研究院 
刘赛 湖南省食品质量监督检验研究院 
陈雄 湖南省食品质量监督检验研究院 
AuthorInstitution
GONG Qin Hunan Institute of food quality supervision inspection and research 
WANG Fang-Bin Hunan Institute of Food Quality Supervision Inspection and Research 
SUN Gui-Fang Hunan Institute of Food Quality Supervision Inspection and Research, 
JIANG Jian Hunan Institute of Food Quality Supervision Inspection and Research, 
CHEN Li Hunan Institute of Food Quality Supervision Inspection and Research, 
XIAO Min Hunan Institute of Food Quality Supervision Inspection and Research, 
LIU Sai Hunan Institute of Food Quality Supervision Inspection and Research, 
CHEN Xiong Hunan Institute of Food Quality Supervision Inspection and Research, 
摘要点击次数: 1738
全文下载次数: 1491
中文摘要:
      目的 研制一种新型的食用油中过氧化值快速检测的试剂盒。方法 探索合适的替代溶剂以及最佳的试剂配比; 依据GB 5009.37-2003原理制作标准比色卡, 在反应载体上进行显色反应, 通过目视比色快速判定待测油脂的过氧化值。在食用油常温存放的3个月内, 同时采用试剂盒方法和国标方法检测其过氧化值, 通过比较验证试剂盒的准确性和稳定性。结果 选择安全低毒的乙醇:异辛烷(70:30, V:V)作为试剂盒实验的混合溶剂, 在配置的简单载体上可快速进行显色反应, 可检测的过氧化值区间范围为0.5~20 meq/kg。试剂盒在常温下存放的3个月内都能保持较好的准确度和稳定性。结论 该试剂盒可用于食用油中过氧化值的快速筛查, 具有广泛的市场应用前景。
英文摘要:
      Objective To develop a new type of rapid detection kit for the determination of peroxide value in oils .Methods The befitting alternative solvents and the best ratio of reagents were explored. The standard color card was established according to national standard method (GB 5009.37-2003) principle, and color reactions can be carried out through the reaction carrier, and then the peroxide value of oils was tested by the naked eye. In order to verify the accuracy and stability of this kit, the peroxide value of oil stored at room temperature for 3 months were obtained and compared by kit’s method and national standard method. Results Ethanol and isooctane (70:30, V:V) which were safe and low-toxic were selected as mixed solvent of kit experiment. It was rapid to determine peroxide value through color reaction in easily accessible carrier. The test range was 0.5~20 meq/kg. This kit maintained high accuracy and stability during 3 months. Conclusion This kit can be applied for the rapid screening of peroxide value in oil, which has broad market prospects.
查看全文  查看/发表评论  下载PDF阅读器