邹游,蓝 草,欧阳少伦,邵琳智,林 峰.液相色谱-串联质谱法测定婴儿奶粉中三聚氰胺残留量的不确定度评估[J].食品安全质量检测学报,2016,7(6):2435-2441
液相色谱-串联质谱法测定婴儿奶粉中三聚氰胺残留量的不确定度评估
Uncertainty evaluation for the determination of melamine residues in infant formula by liquid chromatography-tandem mass spectrometry
投稿时间:2016-03-03  修订日期:2016-06-16
DOI:
中文关键词:  液相色谱-串联质谱法  婴儿奶粉  三聚氰胺  内标法  不确定度
英文关键词:liquid chromatography-tandem mass spectrometry  infant formula  melamine  internal standard method  uncertainty
基金项目:广东出入境检验检疫局科技项目(2015GDK24)
作者单位
邹游 广东出入境检验检疫局检验检疫技术中心 
蓝 草 广东出入境检验检疫局检验检疫技术中心 
欧阳少伦 广东出入境检验检疫局检验检疫技术中心 
邵琳智 广东出入境检验检疫局检验检疫技术中心 
林 峰 广东出入境检验检疫局检验检疫技术中心 
AuthorInstitution
ZOU You Inspection and Quarantine Technology Center, Guangdong Entry-Exit Inspection and Quarantine Bureau 
LAN Cao Inspection and Quarantine Technology Center, Guangdong Entry-Exit Inspection and Quarantine Bureau 
OUYANG Shao-Lun Inspection and Quarantine Technology Center, Guangdong Entry-Exit Inspection and Quarantine Bureau 
SHAO Lin-Zhi Inspection and Quarantine Technology Center, Guangdong Entry-Exit Inspection and Quarantine Bureau 
LIN Feng Inspection and Quarantine Technology Center, Guangdong Entry-Exit Inspection and Quarantine Bureau 
摘要点击次数: 1372
全文下载次数: 1323
中文摘要:
      目的 对液相色谱-串联质谱法测定婴儿奶粉中的三聚氰胺的不确定度进行评估。方法 以GB/T 22388-2008《原料乳与乳制品中三聚氰胺检测方法》为基础改良方法, 测定婴儿奶粉中的三聚氰胺。依据CNAS-GL06: 2006《化学分析中不确定度的评估指南》, 通过数学建模建立不确定度来源鱼骨图, 分析不确定度来源并计算不确定度分量。结果 当奶粉中的三聚氰胺残留量为50 μg/kg时, 测量不确定度为3.70 μg/kg(k=2), 其中液质仪器校准、重现性和偏差对不确定度影响最大。结论 内标法的线性拟合对测量不确定度贡献较小, 对三聚氰胺的常规检测具有重要意义。
英文摘要:
      Objective To evaluate the uncertainty for the determination of melamine residue in infant formula by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Methods Based on GB/T 22388-2008 Determination of melamine in raw milk and dairy products, the original method to measure melamine residue in infant formula was improved. According to CNAS-GL06: 2006 Guidance on evaluating the uncertainty in chemical analysis, the sources of uncertainty of the whole determination procedure were analyzed and calculated based on the mathematical model and fishbone diagram. Results When melamine residue in infant formula was 50 μg/kg, the uncertainty of measurement was 3.70 μg/kg (k=2), and the major sources of uncertainty of measurement were the calibration of LC-MS/MS, repeatability and measuring deviation. Conclusions Standard curve fitting by internal standard method contributes little in combined uncertainty, which is significant for conventional detection of melamine.