于 趁,艾连峰,马育松,姚春毅,贾海涛,剧京亚,张云鹏,侯兰静.基于电感耦合等离子体质谱技术的乳制品中 多种元素的半定量分析方法[J].食品安全质量检测学报,2016,7(2):755-761
基于电感耦合等离子体质谱技术的乳制品中 多种元素的半定量分析方法
Determination of multi elements in dairy products by semi quantitative mi-crowave digestion reaction collision cell inductively coupled plasma mass spectrometry
投稿时间:2015-11-24  修订日期:2016-01-31
DOI:
中文关键词:  半定量分析  多元素  乳制品  碰撞池反应-电感耦合等离子质谱法
英文关键词:semi quantitative analysis  multi elements  dairy products  collision cell reaction-inductively coupled plasma mass spectrometry
基金项目:国家质检总局科技计划项目(2013IK154)
作者单位
于 趁 河北出入境检验检疫局 
艾连峰 河北出入境检验检疫局 
马育松 河北出入境检验检疫局 
姚春毅 河北出入境检验检疫局 
贾海涛 河北出入境检验检疫局 
剧京亚 河北出入境检验检疫局 
张云鹏 河北出入境检验检疫局 
侯兰静 河北出入境检验检疫局 
AuthorInstitution
YU Chen Hebei Entry-Exit Inspection and Quarantine Bureau 
AI Lian-Feng Hebei Entry-exit Inspection and Quarantine Bureau 
MA Yu-Song Hebei Entry-exit Inspection and Quarantine Bureau 
YAO Chun-Yi Hebei Entry-exit Inspection and Quarantine Bureau 
JIA Hai-Tao Hebei Entry-exit Inspection and Quarantine Bureau 
JU Jing-Ya Hebei Entry-exit Inspection and Quarantine Bureau 
ZHANG Yun-Peng Hebei Entry-exit Inspection and Quarantine Bureau 
HOU Lan-Jing Hebei Entry-exit Inspection and Quarantine Bureau 
摘要点击次数: 1690
全文下载次数: 1198
中文摘要:
      目的 采用电感耦合等离子体质谱法(inductively coupled plasma mass spectrometry, ICP-MS)建立乳制品元素分析的He碰撞反应池模式下半定量检测方法。方法 称取0.40~0.50 g样品, 加入5 mL硝酸和1 mL双氧水消解完全后, 碰撞池反应-电感耦合等离子体质谱法半定量测定。结果 通过对样品加标回收及对GSB-8乳粉标准物质的半定量分析, 结果显示, 该方法能够有效消除干扰, 实现对Pb、Cd、Hg、As、Cr、Cu、Zn、Ca等72种元素一次性快速测定, 测定结果偏差为(-19.6%)~(+4.9%), 实际样品回收率为80.4%~104.9%。结论 该方法能快速确定样品中存在的元素及浓度范围, 可以应用于奶制品元素含量扫描分析, 为快速分析评价乳制品中矿物元素提供科学依据。
英文摘要:
      Objective To establish a semi-quantitative detection method in collision reaction pool for the element analysis in dairy products by inductively coupled plasma mass spectrometry (ICP-MS). Methods With adding 5 mL nitric acid and 1 mL hydrogen peroxide, 0.40~0.50 g sample was digested, and then it was determined by semi quantitative microwave digestion reaction collision cell inductively coupled plasma mass spectrometry. Results The sample recovery and semi-quantitative analysis of GSB-8 milk standard reference material showed that this method could effectively eliminate the interference. The implementation of Pb, Cd, Hg, As, Cr, Cu, Zn, Ca and other 64 elements could be simultaneously rapidly determined, the result deviation was in range of (-19.6%)~(+4.9%), and the recoveries of actual samples were 80.4%~104.9%.. Conclusion This method can quickly determine the elements and the concentration range in samples, which can be applied to analyze the element content in dairy and provide scientific basis for the rapid analysis and evaluation of dairy elements.
查看全文  查看/发表评论  下载PDF阅读器