李锦花,李赛花,许海峰,陈丹超,马 明.加速溶剂萃取-高效液相色谱法检测瓦楞纸箱(板)中的多溴二苯醚[J].食品安全质量检测学报,2016,7(1):159-165
加速溶剂萃取-高效液相色谱法检测瓦楞纸箱(板)中的多溴二苯醚
Determination of polybrominated diphenyl ethers in corrugated box (cardboard) by accelerated solvent extraction-high performance liquid chromatography
投稿时间:2015-11-18  修订日期:2015-12-30
DOI:
中文关键词:  加速溶剂萃取  高效液相色谱  瓦楞纸箱(板)  多溴二苯醚
英文关键词:accelerated solvent extraction  high performance liquid chromatography  corrugated box (cardboard)  polybrominated diphenyl ethers
基金项目:国家质量监督检验检疫总局科研项目(2013IK210、2014IK075)
作者单位
李锦花 宁波出入境检验检疫局技术中心 
李赛花 通标标准技术服务有限公司宁波分公司 
许海峰 宁波出入境检验检疫局技术中心 
陈丹超 宁波出入境检验检疫局技术中心 
马 明 宁波出入境检验检疫局技术中心 
AuthorInstitution
LI Jin-Hua Technology Center of Ningbo Entry-Exit Inspection and Quarantine Bureau 
LI Sai-hua Societe Generale de Surveillance SA-China Standard Technology Development Corp Standards Technical Services Co,Ltd Ningbo Branch 
XU Hai-feng Technology Center of Ningbo Entry-Exit Inspection and Quarantine Bureau 
CHEN Dan-chao Technology Center of Ningbo Entry-Exit Inspection and Quarantine Bureau 
MA Ming Technology Center of Ningbo Entry-Exit Inspection and Quarantine Bureau 
摘要点击次数: 1352
全文下载次数: 1657
中文摘要:
      目的 建立一种加速溶剂萃取提取多溴二苯醚的高效液相色谱检测方法。方法 将多层瓦楞纸箱(板)剪至1 cm×1 cm大小, 取适量样品, 以乙醇-丙酮(1:1, V:V)为萃取溶剂, 加速溶剂萃取温度为150 ℃, 萃取压力为1500 psi, 静态萃取10 min, 重复萃取3次后, 用甲醇-水为流动相, 进行梯度洗脱, 226 nm波长进行检测。结果 对8种PBDEs的回收率在95%~105%之间, 精密度试验(n=6)的RSD<3%, 检测限为0.1~0.2 μg/mL, 线性回归系数>0.999。结论 建立的方法与标准方法GB/Z 21276-2007检测结果无明显差异, 可以用于瓦楞纸箱(板)中的PBDEs检测。
英文摘要:
      Objective To establish a method for the determination of polybrominated diphenyl ethers (PBDEs) in corrugated box (cardboard) by high performance liquid chromatography (HPLC) with accelerated solvent extraction. Methods The corrugated box (cardboard) was cut to 1 cm×1 cm. The PBDEs were extracted with ethanol: acetone (1:1, V:V) as extraction solvent in 10 min with static extraction mode and repeated three times by accelerated solvent extraction (ASE) at 150 ℃ and pressure of 1500 psi. The extraction was analyzed by HPLC after using a gradient elution program of methanol-H2O as mobile phase, and detected at 226 nm. Results The recoveries of 8 PBDEs were 95%~105%, the relative standard deviations (RSDs) were under 3% (n=6), the limits of detection were 0.1~0.2 μg/mL, and the linear regression coefficients were above 0.9991. Conclusion The analysis results of PBDEs were satisfied by comparing with the standard method GB/Z 21276-2007. It can be used for the detection of PBDEs in the corrugated box (cardboard).
查看全文  查看/发表评论  下载PDF阅读器