孔维恒,严华,徐珊,高峰,刘鑫,田玲,顾强,张朝晖.微波消解-电感耦合等离子体质谱法同时测定 橄榄油中的18种金属元素[J].食品安全质量检测学报,2015,6(11):4330-4335
微波消解-电感耦合等离子体质谱法同时测定 橄榄油中的18种金属元素
Simultaneous determination of 18 metal elements in olive oil by microwave digestion-inductively coupled plasma-mass spectrometry
投稿时间:2015-09-16  修订日期:2015-11-10
DOI:
中文关键词:  橄榄油  微波消解  元素分析  电感耦合等离子体质谱法
英文关键词:olive oil  microwave digestion  elemental analysis  inductively coupled plasma-mass spectrometry
基金项目:国家质检总局科技计划项目(2014IK107)、江苏省自然科学基金项目(BK20130381)
作者单位
孔维恒 北京出入境检验检疫局 
严华 北京出入境检验检疫局 
徐珊 北京出入境检验检疫局 
高峰 北京出入境检验检疫局 
刘鑫 北京出入境检验检疫局 
田玲 黄埔出入境检验检疫局检验检疫技术中心 
顾强 张家港出入境检验检疫局检验检疫综合技术中心 
张朝晖 北京出入境检验检疫局 
AuthorInstitution
KONG Wei-Heng Beijing Entry-Exit Inspection and Quarantine Bureau 
YAN Hua Beijing Entry-Exit Inspection and Quarantine Bureau 
XU Shan Beijing Entry-Exit Inspection and Quarantine Bureau 
GAO Feng Beijing Entry-Exit Inspection and Quarantine Bureau 
LIU Xin Beijing Entry-Exit Inspection and Quarantine Bureau 
TIAN Ling Inspection and Quarantine Testing Center,Huangpu Entry–Exit Inspection and Quarantine Bureau 
GU Qiang Inspection and Quarantine Testing Center,Zhangjiagang Entry–Exit Inspection and Quarantine Bureau 
ZHANG Zhao-Hui Beijing Entry-Exit Inspection and Quarantine Bureau 
摘要点击次数: 1626
全文下载次数: 1291
中文摘要:
      目的 建立微波消解-电感耦合等离子体质谱(ICP-MS)法同时快速测定进口橄榄油中18种微量金属元素(锂、铍、钛、钴、镍、铜、锌、钼、银、镉、锡、锑、钡、汞、铅、铁、锰、砷)的分析方法。方法 橄榄油经微波消解进行样品前处理, 采用ICP-MS测定, 外标法定量。结果 本方法测定18种金属元素的线性范围宽, 线性关系良好(r>0.999), 检出限低, 各元素的加标回收率在82.3%~110.5%之间, 相对标准偏差均小于5%。结论 本方法具有简单、快速、灵敏度高、准确度高、回收率高等特点, 能够同时对橄榄油中18种元素进行分析。
英文摘要:
      Objective To establish an analysis method for simultaneous determination of 18 trace metal elements (Li, Be, Ti, Co, Ni, Cu, Zn, Mo, Ag, Cd, Ti, Ba, Hg, Pb, Fe, Mn and As) in imported olive oils by microwave digestion-inductively coupled plasma-mass spectrometry (ICP-MS). Methods Olive oil samples were pretreated by microwave digestion and then determined by ICP-MS. The 18 trace metal elements were analyzed quantitatively by external standard method. Results This method had a wide linear range of calibration curves for the determination of 18 metal elements and the linear correlation coefficients were higher than 0.999. The detection limits were lower enough for trace metal elemental analysis. The recoveries for the spiked samples ranged from 82.3% to 110.5% and the relative standard deviations (RSDs) were lower than 5%. Conclusion This method has advantages of simplicity, rapidity, high sensitivity and specificity, high recoveries, and can be used for simultaneous determination of multi-elements in olive oils.
查看全文  查看/发表评论  下载PDF阅读器