孙元昊,刘璎瑛,丁永前,黄煜博,陈继猛.苹果糖度近红外光谱检测波段试验研究[J].食品安全质量检测学报,2015,6(8):3021-3025
苹果糖度近红外光谱检测波段试验研究
Experimental study on near infrared spectroscopy detection of sugar degree of apple
投稿时间:2015-07-01  修订日期:2015-08-13
DOI:
中文关键词:  近红外光谱法  苹果糖度  多元线性回归
英文关键词:near infrared spectroscopy  sugar degree of apple  multiple linear regression
基金项目:
作者单位
孙元昊 南京农业大学工学院, 江苏省智能化农业装备重点实验室 
刘璎瑛 南京农业大学工学院 江苏省智能化农业装备重点实验室 
丁永前 南京农业大学工学院 江苏省智能化农业装备重点实验室 
黄煜博 南京农业大学工学院 江苏省智能化农业装备重点实验室 
陈继猛 南京农业大学工学院 江苏省智能化农业装备重点实验室 
AuthorInstitution
SUN Yuan-Hao Key Laboratory of Intelligent Agricultural Equipment in Jiangsu Province, College of Engineering, Nanjing Agricultural University 
LIU Ying-Ying Key Laboratory of Intelligent Agricultural Equipment in Jiangsu Province, College of Engineering, Nanjing Agricultural University 
DING Yong-Qian Key Laboratory of Intelligent Agricultural Equipment in Jiangsu Province, College of Engineering, Nanjing Agricultural University 
HUANG Yu-Bo Key Laboratory of Intelligent Agricultural Equipment in Jiangsu Province, College of Engineering, Nanjing Agricultural University 
CHEN Ji-Meng Key Laboratory of Intelligent Agricultural Equipment in Jiangsu Province, College of Engineering, Nanjing Agricultural University 
摘要点击次数: 1471
全文下载次数: 2078
中文摘要:
      目的 通过近红外光谱技术对苹果进行无损检测, 具有快速、非破坏性、无试剂分析、安全、高效、低成本等特点。方法 本文运用Matlab7.1, 对苹果的糖度与光谱曲线在不同波段处的相对光强进行多元线性回归分析, 建立了最佳单波长、最佳双波长组合、最佳三波长组合和最佳四波长组合的校正方程。结果 校正方程的相关系数分别为0.621、0.715、0.797和0.822, 标准校正误差分别为1.325、1.218、1.074和0.997Brix°, 相对校正误差分别为11.28%、10.42%、9.63%和9.26%。结论 试验表明用近红外光谱技术无损检测苹果糖度是可行性的, 为今后进一步检测苹果的其他品质奠定基础。
英文摘要:
      Objective Using near infrared spectroscopy technology to detect apple quality. Methods Using Matlab7.1, apple Brix and the spectral curve in different band relative intensity were analyzed with multiple linear regression to establish the best single wavelength, a combination of the best dual wavelength com-bination, the best three wavelength combination and the best four wavelength calibration equation. Results The result showed that correlation coefficient of the calibration equations were 0.621, 0.715, 0.797 and 0.822, the standard error of calibration were 1.325, 1.218, 1.074 and 0.997 Brix°, respectively, and the relative error correction were 11.28%, 10.42%, 9.63% and 9.26%, respectively. Conclusion The study showed that the method of near infrared spectroscopy detection of sugar degree of apple in nondestructive testing was feasible, it could also provide a basis for further detection of other qualities of apple.
查看全文  查看/发表评论  下载PDF阅读器