赵进辉,袁海超,洪 茜,彭义杰,刘木华.表面增强拉曼光谱快速检测四环素水溶液[J].食品安全质量检测学报,2014,5(3):703-706
表面增强拉曼光谱快速检测四环素水溶液
Detection of tetracycline solution based on surface enhanced Raman spectroscopy
投稿时间:2014-02-13  修订日期:2014-03-10
DOI:
中文关键词:  表面增强拉曼光谱  四环素  快速检测
英文关键词:surface enhanced Raman spectroscopy (SERS)  tetracycline  rapid detection
基金项目:国家科技支撑计划项目(2012BAK17B02)、江西省科技厅科技支撑项目(20121BBG70058)
作者单位
赵进辉 江西农业大学工学院/生物光电及应用重点实验室 
袁海超 江西农业大学工学院/生物光电及应用重点实验室 
洪 茜 江西农业大学工学院/生物光电及应用重点实验室 
彭义杰 江西农业大学工学院/生物光电及应用重点实验室 
刘木华 江西农业大学工学院/生物光电及应用重点实验室 
AuthorInstitution
ZHAO Jin-Hui Optics-Electrics Application of Biomaterials Lab, College of Engineering, Jiangxi Agricultural University 
YUAN Hai-Chao Optics-Electrics Application of Biomaterials Lab, College of Engineering, Jiangxi Agricultural University 
HONG Qian Optics-Electrics Application of Biomaterials Lab, College of Engineering, Jiangxi Agricultural University 
PENG Yi-Jie Optics-Electrics Application of Biomaterials Lab, College of Engineering, Jiangxi Agricultural University 
LIU Mu-Hua Optics-Electrics Application of Biomaterials Lab, College of Engineering, Jiangxi Agricultural University 
摘要点击次数: 2114
全文下载次数: 2448
中文摘要:
      目的 为实现水中四环素残留的快速检测, 探索建立四环素水溶液的表面增强拉曼光谱(surface enhanced Raman spectroscopy, SERS)检测方法。方法 以OTR202和OTR103作为表面增强基底, 分析四环素水溶液的SERS光谱, 应用自适应迭代惩罚最小二乘法(air-PLS)扣除SERS的荧光背景, 探讨样品加入量对SERS信号强度的影响, 以1274 cm?1作为特征峰建立四环素水溶液的标准曲线。结果 确定了四环素水溶液的加入量为20 μL, 建立的线性回归方程Y=257.47X 85.165, 相关系数r为0.9897。结论 本研究方法无需前处理, 简便快捷, 为后续水中四环素残留快速现场检测奠定了良好基础。
英文摘要:
      Objective To establish a method for rapid detection of tetracycline residual in water by surface enhanced Raman spectroscopy (SERS). Methods OTR202 and OTR103 were used as enhanced substrate of SERS, and the fluorescence backgrounds of SERS were subtracted by using adaptive iteratively reweighted penalized least squares(air-PLS). The effect of the addition amount of tetracycline solution on SERS intensity was discussed, and 1374 cm?1 was used as the characteristic peak to establish the standard curve of tetracycline solution. Results 20 μL was determined as the best addition amount, the linear regression equation was Y=257.47X 85.165, and the correlation coefficient r was 0.9897. Conclusion A fast and simple method without pretreatment was proposed to detect tetracycline solution, and it provided a reference for the following rapid and field detection of tetracycline residual in water.
查看全文  查看/发表评论  下载PDF阅读器