刘志斌,张建清,蒋友胜,周健,李胜浓,陆少游,林晓仕.同位素稀释-气相色谱/高分辨质谱法测定食品中的指示性毒杀芬指示性毒杀芬[J].食品安全质量检测学报,2014,5(2):475-484
同位素稀释-气相色谱/高分辨质谱法测定食品中的指示性毒杀芬指示性毒杀芬
Determination of toxaphene in food by isotope dilution high resolution gas chromatography/high resolution mass spectrometry
投稿时间:2013-11-11  修订日期:2013-12-06
DOI:
中文关键词:  指示性毒杀芬  同位素稀释-高分辨气相色谱/高分辨双聚焦磁式质谱联用技术  食品
英文关键词:toxaphene indicator  isotope dilution high-resolution gas chromatography/high-resolution double-focusing magnetic mass spectrometry  food
基金项目:国家科技部卫生公益性科研项目(200902009);深圳市科技局重点资助项目(200701012);深圳市医学重点实验室基金项目
作者单位
刘志斌 深圳市疾病预防控制中心;江西省南昌市食品药品检验所 
张建清 深圳市疾病预防控制中心 
蒋友胜 深圳市疾病预防控制中心 
周健 深圳市疾病预防控制中心 
李胜浓 深圳市疾病预防控制中心 
陆少游 深圳市疾病预防控制中心 
林晓仕 深圳市疾病预防控制中心 
AuthorInstitution
LIU Zhi-Bin Shenzhen Center for Disease Control and Prevention;Nanchang Institute for Food and Drug Control 
ZHANG Jian-Qing Shenzhen Center for Disease Control and Prevention 
JIANG You-Sheng Shenzhen Center for Disease Control and Prevention 
ZHOU Jian Shenzhen Center for Disease Control and Prevention 
LI Sheng-Nong Shenzhen Center for Disease Control and Prevention 
LU Shao-You Shenzhen Center for Disease Control and Prevention 
LIN Xiao-Shi Shenzhen Center for Disease Control and Prevention 
摘要点击次数: 2490
全文下载次数: 1872
中文摘要:
      目的 建立食品样品中P26, P50, P62等三大指示性毒杀芬的检测分析方法,为进一步开展常规监测提供技术平台和基础数据。方法 食品样品使用索式提取系统(Soxtec)提取, 提取液依次由30%酸性硅胶柱和氧化铝柱净化, 利用同位素稀释-高分辨气相色谱/高分辨双聚焦磁式质谱联用(ID-HRGC/HRMS)技术对三种指示性毒杀芬单体P26, P50, P62进行定量定性分析。结果 本研究所建成的检测方法相对标准偏差(RSD)小于25%, 回收率可以达到40%~120%; P26, P50, P62的方法检测限分别为0.08、0.02、0.06 pg/g; 方法性能达到开展食品样品中毒杀芬检测技术的要求。结论 该方法可以对食品样品中毒杀芬进行检测, 检测效率高, 结果准确可靠。
英文摘要:
      Objectives To develop the analyzing methods of 3 indicator toxaphenes (P26, P50 and P62) in food samples, so as to provide technical platform and basic data for further routine monitoring. Methods The food sample was extracted by using Soxtec followed by purification on 30% multilayer acidic silica column and neutral aluminum oxides column, utilizing isotope dilution high-resolution gas chromatography/high-resolution double-focusing magnetic mass spectrometry (HRGC/HRMS) to carry out quantitative and qualitative analysis on toxaphene monomer P26, P50, and P62. Results The developed analytical method for three indicator tox-aphenes monomer was built successfully, and suitable for the determination of toxaphene specific congeners in food. The relative standard deviation (RSD) was below 25% and the spiked recoveries were in the range of 40%~120%. The five point calibration curves showed a good linearity for all the congeners (R2 > 0.99). Method detection limit (MDL) was 0.08, 0.02, and 0.06 pg/g for P26, P50, and P62, respectively. Conclusion Three congeners of toxaphene can be measured simultaneously in food sample matrix, the method is efficient and the results are accurate and reliable.
查看全文  查看/发表评论  下载PDF阅读器