张玉,吴慧明,王伟,王建清,白丽萍.高效液相色谱-蒸发光散射检测器同时测定食品中5种甜味剂[J].食品安全质量检测学报,2010,1(1):18-23
高效液相色谱-蒸发光散射检测器同时测定食品中5种甜味剂
Simultaneous determination of five sweeteners in food by high performance liquid chromatography with evaporative light scattering detector
  
DOI:
中文关键词:  高效液相色谱  食品  甜味剂  
英文关键词:High performance liquid chromatography  food  sweetener  
基金项目:浙江省农科院科技创新能力提升工程项目(2008-2010)
作者单位
张玉 浙江省农业科学院农产品质量标准研究所 
吴慧明 浙江大学农药与环境毒理研究所; 
王伟 浙江省农业科学院农产品质量标准研究所 
王建清 浙江省农业科学院农产品质量标准研究所 
白丽萍 浙江省农业科学院农产品质量标准研究所 
AuthorInstitution
Zhang Yu Institute of Quality and Standard for Agriculture Product,Zhejiang Academy of Agriculture Science,Hangzhou 310021,China 
Wu Huiming Institute of Pesticide and Environmental Toxicology,Zhejiang University,Hangzhou 310029,China 
Wang Wei Institute of Quality and Standard for Agriculture Product,Zhejiang Academy of Agriculture Science,Hangzhou 310021,China 
Wang Jianqing Institute of Quality and Standard for Agriculture Product,Zhejiang Academy of Agriculture Science,Hangzhou 310021,China 
Bai Liping Institute of Quality and Standard for Agriculture Product,Zhejiang Academy of Agriculture Science,Hangzhou 310021,China 
摘要点击次数: 2370
全文下载次数: 87
中文摘要:
      建立了高效液相色谱-蒸发光散射检测器同时测定食品中安赛蜜、糖精钠、甜蜜素、三氯蔗糖、阿力甜5种甜味剂的方法。样品中的甜味剂提取后经固相萃取净化,并通过C18柱分离,蒸发光散射检测器测定。结果表明5种甜味剂在5~160mg/L的浓度范围内,相关系数为0.9991~0.9994;方法回收率为92.0%~97.0%,相对标准偏差为0.67%~3.23%。方法最低检出限:安赛蜜为2mg/kg,糖精钠为2.5mg/kg,甜蜜素、阿力甜和三氯蔗糖为5mg/kg。该方法准确、灵敏,是同时检测食品中5种甜味剂的有效方法。
英文摘要:
      A method was developed for simultaneous determination of five sweeteners by high performance liquid chromatography(HPLC).The extraction of sample was cleaned up with solid-phase extraction cartridge.Then the sweeteners were separated on C18 column and determined with evaporative light-scattering detector(ELSD).The results showed that the linear range of the method was 5~160 mg/L with the linear correlation coefficient in the range of 0.9991~ 0.9994.The average recoveries were from 92.0% to 97.0%,and the relative standard deviations(RSDs)were from 0.67% to 3.23%.The detection limit was 2 mg/kg for acesulfame,2.5 mg/kg for saccharin sodium,and 5 mg/kg for cyclamate,alitame and sucralose,respectively.This method is accurate,sensitive.It is an effective method for simultaneous determination of five sweeteners in food.