严 华,崔凤云,别 玮,齐鹤鸣,冯 鑫,张朝晖.超高效液相色谱-同位素稀释质谱法同时测定婴幼儿配方奶粉中10种水溶性维生素[J].食品安全质量检测学报,2020,11(17):5871-5878
超高效液相色谱-同位素稀释质谱法同时测定婴幼儿配方奶粉中10种水溶性维生素
Simultaneous determination of 10 kinds of water soluble vitamins in infant formula by ultra performance liquid chromatography–isotope dilution mass spectrometry
投稿时间:2020-07-20  修订日期:2020-08-24
DOI:
中文关键词:  婴幼儿配方奶粉  水溶性维生素  超高效液相色谱-同位素稀释质谱法  内标法
英文关键词:infant formula  water soluble vitamins  ultra performance liquid chromatography-isotope dilution mass spectrometry  internal standard method
基金项目:国家重点研发计划项目(2019YFC1605100)
作者单位
严 华 北京海关技术中心 
崔凤云 北京海关技术中心 
别 玮 北京海关技术中心 
齐鹤鸣 北京海关技术中心 
冯 鑫 北京海关技术中心 
张朝晖 北京海关技术中心 
AuthorInstitution
YAN Hua Beijing Customs Technology Center 
CUI Feng-Yun Beijing Customs Technology Center 
BIE Wei Beijing Customs Technology Center 
QI He-Ming Beijing Customs Technology Center 
FENG Xin Beijing Customs Technology Center 
ZHANG Zhao-Hui Beijing Customs Technology Center 
摘要点击次数: 677
全文下载次数: 392
中文摘要:
      目的 建立超高效液相色谱-同位素稀释质谱法(ultra performance liquid chromatography-isotope dilution mass spectrometry, UPLC-IDMS)同时检测婴幼儿配方奶粉中10种水溶性维生素(维生素B1 、维生素B2、烟酸、烟酰胺、吡哆醇、吡哆醛、吡哆胺、泛酸、生物素、叶酸)的方法。方法 样品用水溶解后, 加入同位素内标, 用1 mol/L盐酸溶液调节pH至1.7, 再用1 mol/L NaOH溶液调节pH至4.5, 经Agilent ZORBAX SB-AQ C18色谱柱(100 mm×3.0 mm, 1.8 μm)分离, 正离子模式下以0.2%甲酸水溶液和甲醇-乙腈(4:6, V:V)为流动相, 负离子模式下以水和甲醇-乙腈(4:6, V:V)为流动相梯度洗脱, 采用电喷雾离子源, 分别在正、负离子模式下进行多反应监测模式测定, 内标法定量。结果 10种水溶性维生素在10~5000 ng/mL内具有良好的线性关系, 相关系数(r2)大于0.99, 加标回收率为85.7%~115.8%, 相对标准偏差为1.82%~9.67%。结论 该方法简便、快速、灵敏、准确, 可满足婴幼儿配方奶粉中水溶性维生素的检测要求。
英文摘要:
      Objective To establish a method for simultaneous determination of 10 water soluble vitamins (vitamin B1, vitamin B2, niacin, niacinamide, pyridoxin, pyridoxal, pyridoxamine, pantothenic acid, biotin, and folic acid) in infant formula by ultra performance liquid chromatography-isotope dilution mass spectrometry (UPLC-IDMS). Methods Samples were disolved in water and spiked isotope internal standard, the pH value was adusted to 1.7 by 1 mol/L HCl solution and then adjusted pH to 4.5 by 1 mol/L NaOH solution, then separated with Agilent ZORBAX SB-AQ C18 column (100 mm×3.0 mm, 1.8 μm) in gradient elution using 0.2% fomic acid solution and methanol-acetionitrile (4:6, V:V) as mobile phase at positive ionization mode, and using H2O and methanol-acetionitrile (4:6, V:V) as mobile phase at negative ionization mode. Mass spectrometry data was acquired by multiple reaction monitoring (MRM) mode using electrospray ionization at both positive and negative ionization mode. The quantification analysis was carried out by internal standard method. Results The results showed a good linear calibration in the range of 10–5000 ng/mL with correlation coefficients (r2) above 0.99, the recoveries of 10 vitamins ranged from 85.7% to 115.8%, with relative standard deviations of 1.82%–9.67%. Conclusion This method is simple, rapid, sensitive and accurate, and can meet the determination requirements of water soluble vitamins in infant formula.
查看全文  查看/发表评论  下载PDF阅读器