李锦清,唐穗平,綦 艳,黄翠莉,陈满英.液相色谱-离子阱-飞行时间串联质谱法高通量测定聚对苯二甲酸乙二醇酯塑料瓶中10种紫外吸收剂[J].食品安全质量检测学报,2017,8(12):4708-4715 |
液相色谱-离子阱-飞行时间串联质谱法高通量测定聚对苯二甲酸乙二醇酯塑料瓶中10种紫外吸收剂 |
High throughput determination of 10 kinds of ultraviolet stabilizers in polyethylene terephthalate plastic bottles by liquid chromatography-ion trap-time of flight mass spectrometry |
投稿时间:2017-10-25 修订日期:2017-11-27 |
DOI: |
中文关键词: 液相色谱-离子阱-飞行时间串联质谱法 高通量 PET塑料瓶 紫外吸收剂 |
英文关键词:liquid chromatography-ion trap-time of flight mass spectrometry high throughput polyethylene terephthalate plastic bottle ultraviolet stabilizers |
基金项目:广东省质量技术监督局项目(2015CZ09) |
|
|
摘要点击次数: 798 |
全文下载次数: 666 |
中文摘要: |
目的 建立了液相色谱-离子阱-飞行时间串联质谱法(liquid chromatography-ion trap-time of flight mass spectrometry, LCMS-IT-TOF)高通量快速测定聚对苯二甲酸乙二醇酯(polyethylene terephthalate, PET)塑料瓶中10种紫外吸收剂的方法。方法 样品采用三氯甲烷浸泡, 超声萃取, 甲醇-乙腈混合液(3:2, V:V)辅助沉淀净化后用Shim-pack XR-ODS (50 mm×2.0 mm, 1.6 μm)色谱柱分离, 0.1%甲酸水(V:V)和含0.1%甲酸的甲醇-乙腈混合液(3:2, V:V)为流动相进行梯度洗脱。采用电喷雾正离子模式监测, 外标法定量。结果 10种紫外稳定剂在0.05~50 μg/mL范围内线性关系良好, 线性相关系数(r2)均大于0.99; 检出限为0.05~0.1 mg/kg; 3个水平下的加标回收率为91.2%~103.4%; 相对标准偏差(RSD)为1.2%~6.6%。结论 该方法操作简便、快速、准确, 可用于PET塑料瓶中10种紫外吸收剂的同时检测。 |
英文摘要: |
Objective To establish a method for high throughput determination of 10 kinds of ultraviolet stabilizers in polyethylene terephthalate (PET) plastic bottle by liquid chromatography-ion trap-time of flight mass spectrometry (LCMS-IT-TOF). Methods The samples were extracted by trichloromethane and ultrasonic, and purified by methanol and acetonitrile mixture solution (3:2, V:V). The separation of target compounds was carried out on a Shim-pack XR-ODS (50 mm×2.0 mm, 1.6 μm) column using water containing 0.1% (V:V) formic acid and methanol-acetonitrile mixture solution (3:2, V:V) as the mobile phases by gradient elution. The identification of the analytes was achieved in positive electrospray ionization source and quantification was carried out by external standard method. Results The results showed that the standard curves were obtained with good correlation coefficients (r2>0.99) in the range of 0.05~50 μg/mL. The limits of detection (LODs, S/N=3) for 10 kinds of ultraviolet stabilizers were in the range of 0.05~0.1 mg/kg. The mean recoveries for the 10 ultraviolet stabilizers at 3 spiked levels were 91.2%~103.4% with relative standard deviation (RSD) of 1.2%~6.6%. Conclusion This method is simple, rapid, and accurate for the high throughput determination of 10 kinds of ultraviolet stabilizers in PET plastic bottles. |