黄 武,徐金龙,刘建芳,高 平,孙艳波,孙良娟,李 军.高效液相色谱法检测罗非鱼中丁香酚残留量[J].食品安全质量检测学报,2018,9(1):103-106
高效液相色谱法检测罗非鱼中丁香酚残留量
Determination of eugenol residues in tilapia products by high performance liquid chromatography
投稿时间:2017-10-25  修订日期:2017-12-29
DOI:
中文关键词:  高效液相色谱法  丁香酚  残留量  罗非鱼
英文关键词:high performance liquid chromatography  eugenol  residues  tilapia
基金项目:广东检验检疫局科技项目(2016GDK30)、国家质量监督检验检疫总局科技项目(2015IK058)、湛江市财政资金科技专项(2012E0202)
作者单位
黄 武 湛江出入境检验检疫局检验检疫技术中心 
徐金龙 湛江出入境检验检疫局检验检疫技术中心 
刘建芳 湛江出入境检验检疫局检验检疫技术中心 
高 平 湛江市食品药品检验所 
孙艳波 湛江出入境检验检疫局检验检疫技术中心 
孙良娟 湛江出入境检验检疫局检验检疫技术中心 
李 军 湛江出入境检验检疫局检验检疫技术中心 
AuthorInstitution
HUANG Wu Inspection and Quarantine Technology Center of Zhanjiang Entry-Exit Inspection and Quarantine Bureau 
XU Jin-Long Inspection and Quarantine Technology Center of Zhanjiang Entry-Exit Inspection and Quarantine Bureau 
LIU Jian-Fang Inspection and Quarantine Technology Center of Zhanjiang Entry-Exit Inspection and Quarantine Bureau 
GAO Ping Zhanjiang Institute of Supervision and Test on Food and Medicines 
SUN Yan-Bo Zhanjiang Institute of Supervision and Test on Food and Medicines 
SUN Liang-Juan Zhanjiang Institute of Supervision and Test on Food and Medicines 
LI Jun Zhanjiang Institute of Supervision and Test on Food and Medicines 
摘要点击次数: 1066
全文下载次数: 787
中文摘要:
      目的 建立罗非鱼中丁香酚残留量的高效液相色谱分析方法。方法 样品采用乙腈为提取溶剂, 经超声提取、正己烷脱脂净化2次后, 通过高效液相色谱技术检测, 外标法定量。结果 丁香酚在0.1~10.0 mg/L范围内具有良好的线性关系, 相关系数为0.99998; 5.00 g样品中丁香酚残留量的检出限为0.03 mg/kg, 定量限为0.10 mg/kg; 3个添加水平平均回收率为80.5%~101.2%, 相对标准偏差为3.38%~5.39%。结论 本方法具有操作简便、快速、准确的特点, 适用于罗非鱼中丁香酚残留量批量检测。
英文摘要:
      Objective To establish a method for the determination of eugenol residues in tilapia products by high performance liquid chromatography (HPLC). Methods The sample was ultrasonic extracted by acetonitrile, the fat was cleaned up twice by n-hexane, and then the diluted solution was determined by HPLC and quantified by the external standard method. Results The linear range was from 0.1 to 10.0 mg/L with a good correlation coefficients (r=0.99998) for eugenol. The limits of detection and quantitation were 0.03 and 0.10 mg/kg for eugenol based on a 5.00 g sample, respectively. Overall recoveries ranged from 80.5% to 101.2%, and relative standard deviations (RSD) was 3.38%~5.39% for all analytics. Conclusion The method is simple, rapid and accurate, which can be applied to the batch inspection of eugenol residues in tilapia products.