刘建辉,段毅宏,李彦生,张 婷.气相色谱-质谱联用法测定啤酒中N,N-二甲基亚硝胺的不确定度评价[J].食品安全质量检测学报,2017,8(10):3850-3853
气相色谱-质谱联用法测定啤酒中N,N-二甲基亚硝胺的不确定度评价
Evaluation of measurement uncertainty for determination of N-nitrosodimethylamine in beer by gas chromatography-mass spectrometry
投稿时间:2017-05-11  修订日期:2017-09-29
DOI:
中文关键词:  气相色谱-质谱联用法  N,N-二甲基亚硝胺  不确定度
英文关键词:gas chromatography-mass spectrometry  N-nitrosodimethylamine  uncertainty
基金项目:
作者单位
刘建辉 云南省疾病预防控制中心 
段毅宏 云南省疾病预防控制中心 
李彦生 云南省疾病预防控制中心 
张 婷 云南省疾病预防控制中心 
AuthorInstitution
LIU Jian-Hui Yunnan Center for Disease Control and Prevention 
DUAN Yi-Hong Yunnan Center for Disease Control and Prevention 
LI Yan-Sheng Yunnan Center for Disease Control and Prevention 
ZHANG Ting Yunnan Center for Disease Control and Prevention 
摘要点击次数: 1246
全文下载次数: 1342
中文摘要:
      目的 建立气相色谱-质谱联用法(gas chromatography-mass spectrometry, GC-MS)测定啤酒中N,N-二甲基亚硝胺的不确定度评定的方法。方法 从测定方法分析不确定度来源, 计算各不确定度分量, 合成扩展不确定度。结果 该检测方法线性良好, 线性方程为Y=0.00557X-0.0974, 相关系数r=0.9994, 相对标准偏差为1.11%。啤酒样品中的N,N-二甲基亚硝胺测定结果平均值为10.9 μg/mL, 扩展不确定度为1.56 μg/mL。结论 提出的方法适用于啤酒中N,N-二甲基亚硝胺的不确定度评定。
英文摘要:
      Objective To evaluate the measurement uncertainty for determination of N-nitrosodimethylamine in beer by gas chromatography-mass spectrometry (GC-MS). Methods Each source of uncertainty in measurement arising from procedure of testing was analyzed and confirmed according to the guidelines of the uncertainty in measurement. Besides, the combined standard uncertainty and expanded uncertainty of the result were calculated after each uncertainty component was evaluated. Results The detection method had good linearity. The linear equation was Y=0.00557X-0.0974 with the correlation coefficient (r) of 0.9994, and the relative standard deviation was 1.11%. The average N-nitrosodimethylamine content in beer sample was 10.9 μg/mL, and the extended uncertainty was 1.56 μg/mL. Conclusion The method is applicable for the evaluation of measurement uncertainty for the determination of N-nitrosodimethylamine in beer.